HERMETIC COMPRESSOR TROUBLESHOOTING TRAINER
(GESB‐TRS series)

Hermetic Compressor Troubleshooting Trainer

MODELS

GESB‐TRS‐01 : Basic Compressor Motor Winding Troubleshooting Trainer
GESB‐TRS‐02 : Intermediate Hermetic Compressor Troubleshooting Trainer
GESB‐TRS‐03 : Advance Hermetic Compressor Troubleshooting Trainer

The Teach’s Hermetic Compressor Troubleshooting Trainer has been specifically designed for educational use. It guides students through a program of troubleshooting exercises.

GESB‐TRS‐01 is suitable for the students (as beginners) in studying about hermetic compressor. The Instructor will be able to introduce the faults such as open / short winding, compressor body grounded due to winding leakage, or testing the students to find out blind (unmark) hermetic compressor motor connection. The winding position is easy to be changed by means position selector for example from original R‐S‐C to C‐R‐S, S‐R‐C, or C‐S‐R. This model is special designed for winding troubleshooting. There is no external power supply required for this model.

GLOBAL TECH

GESB‐TRS‐02 is suitable for the next level. With live compressor and 10 faults can be introduced to the system; the student will be able to analyze the effect, like the starting relay faulty, broken torque booster, protector faulty, burn out winding, etc.

Model GESB‐TRS‐03 is our advance trainer. The compressor is connected to normal refrigeration circuit. It works to monitor the instruments; voltmeter, ammeter, pressure gauges, and digital temperature for monitoring suction and discharge is provided, so the students will also be able to analyze the compressor malfunction effect and performance at different load.

EXTEND OF SUPPLY (Except for model GESB‐TRS‐01)

Hermetically sealed Compressor, High Pressure Gauge, Low Pressure Gauge, Control Valve, High Pressure Control, Capillary Tube, Starting Capacitor, Running Capacitor, Current Relay (standard), Voltmeter, Ammeter, 10 Electrical Faults.
Additional components for model GESB‐TRS‐03:
Forced Air Condenser, Replaceable Filter Drier, Forced Air Evaporator, and Access Valve.

OPTIONAL STARTING RELAY

GESB‐TRS‐PTC: Solid State Relay (PTCR)

POWER REQUIREMENT

Single Phase, 220~240VAC, 50 Hertz.

DIMENSIONS

GESB‐TRS‐01 : 250 (length) x 200 (height) x 250 (width)
GESB‐TRS‐02 : 800 (length) x 675 (height) x 450 (width) without base frame
GESB‐TRS‐03 : 1100 (length) x 1050 (height) x 600 (width) without base frame

OPTIONAL MOVABLE BASE FRAME WITH STORAGE RACK

800 (length) x 750 (height) x 600 (width) for model RAC‐TRS‐02
1100 (length) x 750 (height) x 600 (width) for model RAC‐TRS‐03

EXPERIMENT MANUAL AND JOB SHEET

The experiment manual and job sheets available.







The picture in this catalog may be modified when necessary because of improvement of the product, modification, or changes in specifications. This catalog is subject to change without notice.