GLOBAL ELECTROMECH (M) SDN BHD

犀利士台灣購買網站https://yescialis.com/,服用一片即可任意享受性福。需求大的ED患者,建議购买犀利士,網站地址https://www.cialislilly.com/比較合適,還可以選擇5mg低劑量,可以天天服用。

GLOBAL TECH

DOMESTIC AIR CONDITIONING TRAINER
(RECONFIGURE series)

Domestic Air Conditioning Trainer

Window Air Conditioning System with Reverse Cycle (Model: GESB‐WIN‐R2) complete with Fault Simulators

Reconfigures series trainers are actually the same with original series, but in this series trainer; some hidden components have been reposition outside its casing for easy access and analyzing.

Shut‐off valves are used for introducing the mechanical faults fit in the strategic location along refrigeration lines, so the students will be familiar with the effect; such as Filter Drier clogged or Expansion Valve clogged / stuck closed. As an option, 10 Electrical Fault Simulators can be fit to the system for testing or improving the student capabilities.

The original casing has been modified and it is possible to sight inside by means transparent acrylic.

OPTIONAL MODELS

GESB‐WIN‐R1 : Window Air Conditioning System (Cooling Only)
GESB‐WIN‐R2 : Window Air Conditioning System with Reverse Cycle
GESB‐SPT‐R1 : Split Air Conditioning System (Cooling Only)
GESB‐SPT‐R2 : Split Air Conditioning System with Reverse Cycle

GLOBAL TECH

EXTEND OF SUPPLY

Hermetic sealed Rotary Compressor, Forced Air Condenser, Filter Drier, Capillary Tube, Forced Air Evaporator, Suction Accumulator, High and Low Pressure Control, Pressure Gauges, Manual Valves, Sight Glasses with moisture indicator, Access Valve, Thermostat, Temperature Display with thermocouple sensors (selectable), Electrical Switchboard with Voltmeter and Ammeter. Unit protected by Earth Leakage Circuit Breaker; with additional:
For GESB‐WIN‐R2 : 4 Way Reversing Valve, Check Valves
For GESB‐SPT‐R1 : Liquid Stop Valve, and Gas Stop Valve.
For GESB‐SPT‐R1 : 4 Way Reversing Valve, Check Valves

OPTIONAL FAULT SIMULATORS

GSEB‐WIN‐F10 : 10 Electrical fault simulators (for Model GESB‐WIN‐R1 and GESB‐WIN‐R2)
GESB‐SPT‐F10 : 10 Electrical fault simulators (for Model GESB‐SPT‐R1 and GESB‐SPT‐R2)

POWER REQUIREMENT

Single Phase, 220~240VAC, 50 Hertz.

DIMENSIONS

1100 (length) x 1050 (height) x 600 (width) without base frame

OPTIONAL MOVABLE BASE FRAME WITH STORAGE RACK

1100 (length) x 750 (height) x 600 (width)

EXPERIMENT MANUAL AND JOB SHEET

The experiment manual and job sheets available.










The picture in this catalog may be modified when necessary because of improvement of the product, modification, or changes in specifications. This catalog is subject to change without notice.