BASIC COMFORT AIR CONDITIONING SYSTEM
(Model: GESB‐BAS‐01)

Basic Comfort Air Conditioning System


As per extend of supply, it will be suitable for learning basic refrigeration cycle for comfort air‐conditioning systems. Color‐coded piping makes it easy to explain the refrigerant state in the system. Hand shut‐off valves can also be used as mechanical faults such as filter drier clogged or restriction in the expansion valve due to foreign materials or air inside. If it is required, select the optional system fault simulators to challenge/improve the student ability in basic troubleshooting skills.

EXPERIMENTAL CAPABILITIES

  • Analyzing the components function.
  • Determination Compressor input power.
  • Determination degree of superheats in the Evaporator and suction line.
  • Determination degree of desuperheat in the discharge line.
  • Determination degree of sub‐cooled in the Condenser and liquid line.
  • Determination of the Coefficient of Performance.
  • Plotting refrigeration cycle into Pressure Enthalpy Diagram.
  • Determination heat rejection in the Condenser (Qc).
  • Determination Refrigerating Effect (qe) and Refrigerating Capacity (Qe)..
  • Investigating of the system malfunction based on electrical circuit.
  • Investigating of the system malfunction based on refrigeration circuit.

GLOBAL TECH

EXTEND OF SUPPLY

Hermetic sealed reciprocating Compressor, Forced air Condenser and Evaporator with variable fan speed control, Filter Drier, Capillary Tube and TXV (internal equalizer) for standard expansion devices, Suction Accumulator, 3 sight glasses with moisture indicator 4 Manual Valves, 2 Access Valves, Low Pressure Gauge (Bourdon type), High Pressure Gauge (Bourdon type), Low Pressure Control, High Pressure Control, Thermostat, Temperature Display with 7 selectable thermocouple sensors, Electrical Switchboard with Voltmeter and Ammeter. Unit protected by Earth Leakage Circuit Breaker.

POWER REQUIREMENT

Single Phase, 220~240VAC, 50 Hertz

DIMENSIONS

1100 (length) x 1050 (height) x 600 (width) without base frame

OPTIONAL MOVABLE BASE FRAME WITH STORAGE RACK

1100 (length) x 750 (height) x 600 (width)

EXPERIMENT MANUAL AND JOB SHEET

The experiment manual and job sheets available.










The picture in this catalog may be modified when necessary because of improvement of the product, modification, or changes in specifications. This catalog is subject to change without notice.